Concept Controls Logo

Looking to rent with us? We're here to assist you every step of the way. Please complete the form below to provide us with details about your rental needs. The more information you can share, the better we can tailor our services to match your requirements.

Need assistance? Our Service Team is here to help. Please fill out the form below with your question or problem. Be as detailed as possible to help us understand your situation better. Once you submit the form, our team will review your request and get back to you promptly.

E3 Point

Toxic/combustible gas monitor for commercial operations

Honeywell Logo

E3 Point Family of Gas Detectors

E3Point is capable of detecting the widest range of toxic and combustible gases found in commercial building spaces and outbuildings. It can be used as a standalone unit with single or dual-gas detection (i.e. using a remote sensor) or deployed as a networkable device (interoperable with BACnet, Modbus or other Building Automation System); E3Point also functions with existing controller-based gas monitoring systems and wired-wireless gas monitoring system components.

Highlights

E3Point uses Demand Control Ventilation—through relays, Building Automation System (BAS) or controller—to increase energy savings, extend fan life and align with green building best practices. In its network configuration, E3Point also optimizes HVAC, fire/smoke, surveillance and other building systems performance.

Intelligent product design reduces the unit’s cost of ownership while increasing flexibility of application. Smart sensors are pre-calibrated, auto-configure upon set-up and operate continuously on patented Reflex©technology which continuously monitors sensor cell condition and alerts user to fault status. The plug-n-play sensor cartridge, user-friendly menu and wiring options simplify installation and maintenance, and reduce the cost of gas monitoring over the life of the unit.

Sensor Library
Advanced electrochemical (for toxic gases) and catalytic bead (for combustible gases sensor performance

Smart Connections

Works with virtually any BAS including BACnet and Modbus

Easy Setup

E3 Point’s plug-n-play sensor is factory calibrated and works out of the box. When installed, E3 Point automatically configures for quick operation.

FEATURES &
BENEFITS

Reflex Technology
Patented tech that adds an extra degree of precision and diligence to sensor monitoring to make doubly sure you’re safe. Reflex bounces electrical signals into the E3 Point electrochemical sensor cell at regular intervals, a form of electronic bump testing and continuous monitoring of cell response
Cost Effective
  • Saves energy through Demand Control Ventilation (DCV)
  • Simplifies installation/maintenance through plug-n-play sensor
  • Remote sensor option provides dual gas monitoring (standalone version only)
  • Optimizes BAS, fire, ventilation and other security systems
Flexible Operation
  • Comes in standalone, standalone with remote (dual gas mode) or network versions
  • Connects to analog or digital systems
  • Works with virtually any BAS including BACnet, Modbus
  • Wall or duct mount
  • Factory-calibrated cartridges

Applications:

Parking Structures
Chillers
Mechanical Rooms
Office Towers
Commercial Buildings
Shopping Centres
Swimming Pools
Golf Courses
Schools and Universities
Laboratories

One Stop Shop for Your Needs

Get Calibrated

Make sure your devices are properly calibrated.

Book a Service

Ensure your device is in good working order.

Rent Today!

Need a device on short or long term?.